2.
Card Electrophysiol Clin ; 15(4): 433-445, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37865517

RESUMO

Heart failure in patients with congenital heart disease (CHD) stems from unique causes compared with the elderly. Patients with CHD face structural abnormalities and malformations present from birth, leading to altered cardiac function and potential complications. In contrast, elderly individuals primarily experience heart failure due to age-related changes and underlying cardiovascular conditions. Cardiac resynchronization therapy (CRT) can benefit patients with CHD, although it presents numerous challenges. The complexities of CHD anatomy and limited access to appropriate venous sites for lead placement make CRT implantation demanding.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Insuficiência Cardíaca , Humanos , Idoso , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
3.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799799

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

4.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37283271

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Eletrocardiografia/métodos
5.
Pediatr Cardiol ; 44(5): 1160-1167, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36625944

RESUMO

BACKGROUND: Chronic right ventricular (RV) apical pacing in patients with congenital complete atrioventricular block (CCAVB) is associated with left ventricle (LV) dyssynchrony and dysfunction. Hence, alternative pacing sites are advocated. The aim of this study was to compare LV function using STE in selected patients with LV epicardial pacing (LVEp) vs. RV transvenous pacing (RVSp). METHODS: This was a single-center, retrospective study in patients with CCAVB who underwent permanent pacemaker implant at age ≤ 18 years. Age- and gender-matched patients with a normal heart anatomy and function served as the control group. LV function was comprehensively assessed by conventional 2D Echocardiography and speckle-tracking echocardiography (STE). RESULTS: We included 24 patients in the pacemaker group [27.6% male, mean age of 17.1 at last follow-up, follow-up duration of 8.7 years, RVSp (n = 9; 62.5%)] compared to 48 matched healthy controls. Shortening fraction (SF) and ejection fraction (EF) were normal and similar between cases and controls. However, STE detected abnormal LV function in the pacemaker group compared to controls. The former demonstrated lower/abnormal, Peak Longitudinal Strain myocardial (PLS Myo) [- 12.0 ± 3.3 vs. - 18.1 ± 1.9, p < 0.001] and Peak Longitudinal Strain endocardial (PLS endo) [- 16.1 ± 4.1 vs. 1.7 ± 1.7, p < 0.001]. STE parameters of LV function were significantly more abnormal in LVEp vs. RVSp subgroup as demonstrated by lower values for PLS Myo (- 10.1 ± 3.2 vs. - 13.1 ± 2.9, p = 0.03) and PLS Endo (- 13.8 ± 4.4 vs. - 17.5 ± 3.3, p = 0.03). CONCLUSION: STE was more sensitive in detecting subtle differences in LV function relative to standard conventional 2D echocardiography (SF and EF) in selected patients with CCAVB and a permanent pacemaker. Furthermore, STE demonstrated that transvenous RV septal pacing was associated with better LV systolic function preservation than LV epicardial pacing for comparable post-implant intervals.


Assuntos
Ventrículos do Coração , Disfunção Ventricular Esquerda , Humanos , Masculino , Adolescente , Feminino , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Estimulação Cardíaca Artificial , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/terapia , Bloqueio Cardíaco/congênito , Função Ventricular Esquerda , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia
7.
Pediatr Cardiol ; 2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36063175

RESUMO

Appropriate non-invasive assessments (ECHO/ECG) of cardiac resynchronization pacing therapy (CRT) among younger patients (pts) with/without (w/wo) congenital heart disease (CHD) are not established. Ejection fraction (EF) and QRS can be unreliable due to anatomy, surgical repairs, and pre-existing pacemakers (PM). This study correlates updated non-invasive studies, including newer strain values, with clinical and invasive hemodynamic assessments of CRT response in the young. Sixteen pts (mean age 18.5 ± 6 years, 10/16 with pre-existing pacemakers) underwent CRT for heart failure (NYHA II-III). CHD included septal defects and Tetralogy of Fallot. Assessment of CRT efficacy was based on clinical findings, direct catheterization studies [pressures, contractility indices (dP/dt-max)], ECG changes, and ECHO studies [including updated global (GLS), left atrial strain (LAS), and sphericity indices] pre- and at 1-month and 1-year post-CRT. After 1 year following CRT, all pts improved (II-III to I-II) in clinical NYHA status. Contractility (dP/dt) increased (932 ± 351 vs 561 ± 178.7 mmHg-sec [p = 0.001]). QRS duration shortened only among pts with pre-existing PM (160 ± 25 vs 134 ± 25 ms [p = 0.02]). Standard ECHO parameters, including chamber dimensions and EF, showed no appreciable changes from pre-CRT values. However, endocardial GLS [(- 6.4 vs. - 9.6%) p = 0.0003] and LAS [(- 5.8 vs - 9.3%) p = 0.02] values significantly improved. Although CRT is applicable to younger pts, accurate non-invasive evaluations of response are lacking. This study establishes that newer strain values better correlate with clinical and hemodynamic changes over other parameters and offer more appropriate assessments of CRT response.

9.
Pediatr Cardiol ; 43(3): 700-703, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34783874

RESUMO

Cardiac amyloidosis is a rare cause of cardiomyopathy, reported exclusively in adults. We report the first known case presenting in childhood. A 12-year-old boy presented with syncope and diagnosed with ventricular non-compaction by echocardiography. Eventual genetic testing confirmed a TTR gene mutation associated with hereditary transthyretin amyloidosis.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Adulto , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/diagnóstico , Neuropatias Amiloides Familiares/genética , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Criança , Testes Genéticos , Humanos , Masculino , Pré-Albumina/genética , Síncope/etiologia
10.
JACC Clin Electrophysiol ; 7(11): 1437-1472, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34794667

RESUMO

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Adulto , American Heart Association , Criança , Eletrônica , Humanos , América Latina , Estados Unidos
12.
Cardiol Young ; 31(11): 1738-1769, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34338183

RESUMO

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Assuntos
Cardiologia , Desfibriladores Implantáveis , American Heart Association , Eletrofisiologia Cardíaca , Criança , Consenso , Eletrônica , Humanos , Estados Unidos
14.
Heart Rhythm ; 18(11): 1888-1924, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34363988

RESUMO

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Assuntos
Eletrofisiologia Cardíaca/normas , Desfibriladores Implantáveis , Técnicas de Diagnóstico Cardiovascular , Criança , Consenso , Remoção de Dispositivo , Diagnóstico por Imagem , Humanos , Estados Unidos
15.
Indian Pacing Electrophysiol J ; 21(6): 349-366, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34333142

RESUMO

Guidelines for the implantation of cardiac implantable electronic devices (CIEDs) have evolved since publication of the initial ACC/AHA pacemaker guidelines in 1984 [1]. CIEDs have evolved to include novel forms of cardiac pacing, the development of implantable cardioverter defibrillators (ICDs) and the introduction of devices for long term monitoring of heart rhythm and other physiologic parameters. In view of the increasing complexity of both devices and patients, practice guidelines, by necessity, have become increasingly specific. In 2018, the ACC/AHA/HRS published Guidelines on the Evaluation and Management of Patients with Bradycardia and Cardiac Conduction Delay [2], which were specific recommendations for patients >18 years of age. This age-specific threshold was established in view of the differing indications for CIEDs in young patients as well as size-specific technology factors. Therefore, the following document was developed to update and further delineate indications for the use and management of CIEDs in pediatric patients, defined as ≤21 years of age, with recognition that there is often overlap in the care of patents between 18 and 21 years of age. This document is an abbreviated expert consensus statement (ECS) intended to focus primarily on the indications for CIEDs in the setting of specific disease/diagnostic categories. This document will also provide guidance regarding the management of lead systems and follow-up evaluation for pediatric patients with CIEDs. The recommendations are presented in an abbreviated modular format, with each section including the complete table of recommendations along with a brief synopsis of supportive text and select references to provide some context for the recommendations. This document is not intended to provide an exhaustive discussion of the basis for each of the recommendations, which are further addressed in the comprehensive PACES-CIED document [3], with further data easily accessible in electronic searches or textbooks.

16.
Indian Pacing Electrophysiol J ; 21(6): 367-393, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34333141

RESUMO

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.

17.
Cardiol Young ; 30(5): 740-742, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32308173

RESUMO

Symptomatic, circulatory collapse occurred in an unvaccinated child with repaired congenital heart and a backup pacemaker during an Influenza B viral infection with complete atrioventricular block and pacemaker non-capture. Ventricular arrhythmias occurred during her collapse. Atrioventricular conduction recovered within 24 hours. Influenza-associated cardiac inflammation can adversely affect patients with repaired CHD. Proactive immunisation is strongly recommended.


Assuntos
Bloqueio Atrioventricular/etiologia , Cardiopatias Congênitas/complicações , Influenza Humana/complicações , Choque/etiologia , Bloqueio Atrioventricular/terapia , Criança , Eletrocardiografia , Feminino , Cardiopatias Congênitas/prevenção & controle , Humanos , Vacinas contra Influenza , Marca-Passo Artificial , Choque/terapia
18.
Pediatr Cardiol ; 40(6): 1183-1189, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31177302

RESUMO

African American (AA) adults are reported to have lower levels of cardiorespiratory fitness (CRF) as compared to Caucasian adults. CRF is linked to cardiovascular morbidity and mortality. We hypothesized that the disparities start early in childhood. This was a retrospective analysis of the cardiopulmonary exercise test (CPET). We included normal healthy children, ≤ 18 years of age, who had normal electrocardiograms and normal cardiac function. We excluded patients with congenital heart disease, obesity and suboptimal exercise test. The entire cohort was divided into two groups based on race (Caucasian vs. AA) and then further subcategorized by gender. The cohort of 248 patients had a mean ± SD age of 14.4 ± 2.1 years. 158 (60.8%) were males and 158 (60.8%) were Caucasians. Oxygen consumption was higher among Caucasian children when compared to the AA children (48.7 ± 7.9 vs. 45.4 ± 7 mL/kg/min, p = 0.01). This racial disparity continued to persist when comparisons were performed separately for girls and boys. Upon comparing the four groups, the AA females were found to have the lowest values of VO2max, exercise time and METS (p = 0.001). Thus, in conclusion, the AA children have significantly lower level of CRF, as measured by VO2max and exercise time. The racial disparity is independent of gender. African American females show the lowest level of aerobic capacity. The findings of our study suggest that the racial disparity in the CRF levels seen in the adult population may begin early in childhood.


Assuntos
Aptidão Cardiorrespiratória , Tolerância ao Exercício/fisiologia , Disparidades nos Níveis de Saúde , Consumo de Oxigênio , Adolescente , Negro ou Afro-Americano/estatística & dados numéricos , Estudos de Casos e Controles , Criança , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Estudos Retrospectivos , População Branca/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS